HDS1021M Handheld Digital Storage Oscilloscope & Multimeter User Manual www.owon.com.cn www.owon.com.hk
OWON HDS1021M Handheld DSO & DMM 2-Safety Information 2.Safety Information In order to ensure the correct using and the bes
OWON HDS1021M Handheld DSO & DMM 2-Safety Information adapter appointed by the manufacturer and subject to approval of bein
OWON HDS1021M Handheld DSO & DMM 2-Safety Information ● Voltage ratings that are mentioned in the warning are giver as lim
OWON HDS1021M Handheld DSO & DMM 3-General Characteristics 3. General Characteristics Oscilloscope Record length of 6
OWON HDS1021M Handheld DSO & DMM 4-Performing the General Inspection 4. Performing the General Inspection 4.1 Performing the General Ins
OWON HDS1021M Handheld DSO & DMM 5-Input connections 5. Input Connections 5.1 Input Connections See the following figu
OWON HDS1021M Handheld DSO & DMM 5-Input connections 5.2 Description for Front Panel and Keys See the following figure 3:
OWON HDS1021M Handheld DSO & DMM 5-Input connections z With the combination application of the four keys OSC ◄, OSC ►, OS
OWON HDS1021M Handheld DSO & DMM 6-Using the scope 6. Using the Scope 6.1 About this Chapter This chapter provides a step-
OWON HDS1021M Handheld DSO & DMM 6-Using the scope 1. Battery electric quantity indicating symbols, including , , and
Mar. 2012 edition Ver1.1 Copy Right in this Manual © Lilliput Company. All rights have been reserved. The Lilliput’s products are un
OWON HDS1021M Handheld DSO & DMM 6-Using the scope 16. Waveform of the input signal. 17. Waveform display area. 6.4 Na
OWON HDS1021M Handheld DSO & DMM 6-Using the scope ▲/▼ – Volts/Div See the following figure 6: figure 6: Voltage Unit Sca
OWON HDS1021M Handheld DSO & DMM 6-Using the scope screen, shown as the following figure. ◄/► – Time ▲/▼ – Trig See the fo
OWON HDS1021M Handheld DSO & DMM 6-Using the scope 1. Press MENU key and the function menu appears on the right side of t
OWON HDS1021M Handheld DSO & DMM 6-Using the scope 6.9 Automatic Zero-returning of Trigger Horizontal Position and 50% se
OWON HDS1021M Handheld DSO & DMM 6-Using the scope figure 10: Automatic Scope Measurements 6.11 Freezing the Screen You
OWON HDS1021M Handheld DSO & DMM 6-Using the scope displayed at the bottom of the screen. 3. Press the F3 key to select Av
OWON HDS1021M Handheld DSO & DMM 6-Using the scope figure 13: Persistence to Observe Dynamic Signals 6.14 Using Peak Dete
OWON HDS1021M Handheld DSO & DMM 6-Using the scope they are gathered in the following three different modes, such as sampl
OWON HDS1021M Handheld DSO & DMM 6-Using the scope figure 15: AC-Coupling 6.16 Reversing the Polarity of the Displayed Wa
General Warranty The Lilliput warrants that the product will be free from defects in materials and workmanship for a period of three years from the d
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter 7. Using the Multimeter 7.1 About this Chapter This chapter provides
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter operation mode and Auto refers to the measuring range in automatic op
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter 7.4.1 Measuring Resistance Values To measure a resistance, do the fol
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter figure 19: Diode Measurement 7.4.3 On-off Test To perform an On-off
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter 7.4.4 Making a Capacitance Measurement To measure a capacitance, do t
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter figure 22: DC Voltage Measurement 7.4.6 Making a AC Voltage Measurem
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter 7.4.7 Making a DC Current Measurement To measure a DC current which i
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter figure 25: DC Current Measurement for 20A 7.4.8 Making an AC Current
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter To measure an AC current which is larger than 400 mA, do the followin
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter figure 28: Freezing the Readings 7.6 Taking a Relative Measurement A
OWON HDS1021M Handheld DSO & DMM Contents Table of Contents Chapter
OWON HDS1021M Handheld DSO & DMM 7-Using the Multimeter 7.7 Selecting Automatic/Manual Range Adjustment The defaulted range m
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope 8.Advanced Function of Oscilloscope 8.1 About this Chapter This
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope Probe 1X 10X 100X 1000X Select one according the probe attenuat
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope 8.2.2 Make Open and Close Settings on Channel Press F2 Channel
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope 4. Press the OSC OPTION key and the following is shown on the
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope Normal Single triggering condition detected. Acquisition of
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope Odd Field Even Field Make a video odd field trigger synchroniza
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope decrease Set the off time to decrease. Reset Off Time Reset
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope Function menu Settings Description Type Vectors Dots The vec
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope 1. Press MENU, the function menu will appear on the right of t
OWON HDS1021M Handheld DSO & DMM Contents 6.4 Navigating a Menu ···························
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope Now, you can see a screen that looks like the following figure
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope Freq Measure the frequency of the signal. Period Measure the
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope Term interpretation Vpp: Peak-to-Peak Voltage. Vmax: The maximu
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope 1. Press the MENU key and the function menus are displayed at
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope screen. Then, adjust the OSC ▲ or OSC ▼ and you can find that
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope 3. Press F2 Mode to select Horizontal- Vertical. 4. Press F3 to
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope 2. Press the MENU ▲ or MENU ▼ key to select the SYS STAT. Four
OWON HDS1021M Handheld DSO & DMM 8-Advanced Function of Oscilloscope The screen that looks like the following figure 49, 50 will be
OWON HDS1021M Handheld DSO & DMM 9-Trouble Shooting 9.Trouble Shooting 1. The oscilloscope does not power up. It may b
OWON HDS1021M Handheld DSO & DMM 10-Appendix 10.Appendix 10.1 Appendix A: Specifications 10.1.1 Oscilloscope Only if
OWON HDS1021M Handheld DSO & DMM Contents 7.6 Taking a Relative Measurement················
OWON HDS1021M Handheld DSO & DMM 10-Appendix Vertical Analog digital converter(A/D) the resolution of 8 bits Sens
OWON HDS1021M Handheld DSO & DMM 10-Appendix Probe 1X position 10X position Bandwidth Up to 6 MHz (DC) Up to
OWON HDS1021M Handheld DSO & DMM 10-Appendix Alternating Current (AC) Range Accuracy Resolution 40.00mA ±1.5%±3 dig
OWON HDS1021M Handheld DSO & DMM 10-Appendix Power Adapter Power supply 100-240 V AC 50/60Hz Power output 8.5
OWON HDS1021M Handheld DSO & DMM 10-Appendix allowed to be cleaned by soft detergent or fresh water. Do not use any
OWON HDS1021M Handheld DSO & DMM Contents 10.APPENDIX······································
OWON HDS1021M Handheld DSO & DMM 1-Declaration of Conformity 1.Declaration of Conformity 1.1 Declaration of Conformity HDS1021M H
OWON HDS1021M Handheld DSO & DMM 1-Declaration of Conformity 1.2 Package Contents See the picture below. This picture is only for
Komentarze do niniejszej Instrukcji